All-in-one (Compact) / Scroll type / APCC Series / 10-30 TR
Two-Pieces / Scroll type / APCA Series / 5 - 70 TR
Two-Pieces / Screw type / APSA Series / 75 - 115 TR
Rooftop packaged units (series APCC, APCA and APSA) consist of an air handling unit with DX (Direct Expansion) evaporator coil and a condensing unit including a compressor, condenser and refrigeration cycle equipment; it can use a heating coil for cold seasons as well. These air conditioning models are suitable for such places as shops, community halls, industrial/sport/exhibition complexes, and indoor amusement parks.

Features of rooftop packaged units (Series APCC, APCA and APSA):
Equipped with scroll and screw compressors (made by Copeland/Danfoss and
Bitzer/Hanbell Companies)
- Capable of being built either in one or in two pieces
- compatible with Industrial environments
- Using finned tube type evaporators
- Utilization of Centrifugal type evaporator fans
- External pressure drop of 100 Pa
- Axial condenser fans equipped with assembled fan motors
- casing with galvanized sheets covered with electrostatic paint
- the evaporator part is Fully double-walled with 25 mm polyurethane insulation and aluminum profiles
- Applicable under any weather conditions
- Fully bolt-and-nut assembling without any welding

Machine-installed conventional equipment:
- High and Low pressure mechanical control switches
- Compressor suction and liquid line valves for repair and maintenance
- Microprocessor controller with digital screen
- Mechanical temperature switch to protect the evaporator
- Water-flow differential pressure switch
- High and Low pressure transmitters
- Safety valve on the liquid line
- Compressor electronic protection module
- High and Low pressure indicator mechanical gauges for each separate circuit
- Compressor heater
- Connectability to the integrated BMS through the Modbus protocol
- G2 aluminum washable filter
- Phase control for input phases and phase symmetry

Custom-made possibilities:
- Rooftop Packaged unit with compressors able to store up to 100% of the refrigeration load in the machine unit structure
- Designability and producibility with inverter compressors
- Inverter installability to control the speed of condenser fans
- Designability with low-noise operation
- Designability with super low-noise operation
- heat exchangers producibility with copper pipes, copper fins and coated fins (e.g. Blue, Gold, etc.)
- Usability of different anti-corrosion coatings for condenser heat exchangers (e.g. Blygold, Heresite, Sakaphen, etc.)
- Usability of open-type screw compressors for specific applications
- Usability of 0-10 V or 4-20 mA analog inputs for set-point variations
- Controllability of all equipment through PLC with such brands as Siemens, Schneider Electric, etc.
- Usability of micro-channel condenser heat exchangers
- Operability during all four seasons
- Inter-connectability of multiple chillers manageable as a single unit and spare chillers and working hours management
- EC-type condenser fans
- Condenser centrifugal fans for special applications
- Usability of Plug and Backward-type evaporator fans
- Usability of an extra oil separator for each circuit
- F7 bag filter
- Digital inputs for upstream control
- Usability of thermostats in the upstream
- Designability and Installability of return fans
- Designability and producibility Hygienically
- Designability and producibility with chemical filters or such high-efficiency filters as HEPA, Activated Carbon, etc.
- Designability and producibility with steam heating heat exchangers, hot water or heating elements when heat is needed
- Usability of protective mechanical equipment including propulsion line silencers (mufflers), suction line accumulators and liquid line receivers
- Installability of controlling equipment to reduce energy consumption
- Installability of soft starters
- Usability of anti-freeze heater on the evaporator
- Installability of economizer using plate heat exchangers
- Installability of mechanical filters on suction and liquid lines
- Installability of such heat recovery heat exchangers as air-to-air or energy-recycling cycle
- Usability of protective grids on the machine lower levels and on the condenser coils
- Usability of electronic expansion valves in refrigeration circuits
- Installability of quick-connection hydraulic equipment
- Usability of water-seal chambers to protect condenser fans and coils in non-operational seasons
- Spring-type shock absorbers
- Possibility of equipping the system to different-dimension touch screens